fbpx

search

HUD Releases Initial Look at NSPIRE Inspection Standards

On August 20, 2019, HUD released the first of the new NSPIRE protocols which will be expected to become active once the pilot/demonstration program has concluded. This is a first look at what deficiencies will look like under NSPIRE, the inspection protocol which will eventually take the place of UPCS. HUD has created a webpage where they are going to be posting new deficiencies as they work through the pilot program. To clarify, these standards are not currently in effect, but we expect these new standards to be revised and additional standards to be released.
This inspection protocol is a significant departure from UPCS, which used a series of severity ratings. Instead of determining what makes something (1) minor, (2) major and (3) severe, NPSIRE will list a series of possible deficiencies for each item, and inspectors will make a Yes or No determination.
In this initial release, HUD chose to provide five examples: (1) Chimneys, (2) Exit Signs, (3) Sinks, (4) Smoke Detectors, and (5) Trash Chutes.
    New Standards, New Style for Deficiencies ​​​​​​
    Using Chimneys as the first example, the deficiency has changed from the existing three-tier set of deficiencies under UPCS to a new standard that has seven different deficiencies. The additional new standards represent new tests which will be performed on chimneys during an inspection, including new procedures for testing dampers and checking the chimney for clogs (which will be tested by reviewing documentation from a regular cleaning).
    New Concepts of Life-Threatening Deficiencies​​​​​​
    In reviewing the one example of Chimneys, HUD has also greatly expanded the definition of "Life-Threatening Health & Safety". Currently, there are less than ten EH&S issues in the entire UPCS protocol, and in the one example of Chimney, five of the seven deficiencies are considered Life-Threatening.
    This trend continues with other items, including the sink, which will define missing components, inoperable hardware, and clogged drains all to be life-threatening.
    New Standards for Smoke Detectors ​​​​​​NSPIRE will also introduce new standards for smoke detectors which may exceed local code requirements. Under UPCS, there is a requirement for there to be one smoke detector per floor, per dwelling unit. Under NSPIRE this is extending to one per bedroom and one per floor (in the hallway, living room, etc). Similar to Chimneys, smoke detectors are extending from one deficiency to three separate deficiencies: (1) Missing from Bedrooms (2) Obstructed, (3) Inoperable.
    Notice of Demonstration To Assess the National Sta...
    Owner's Responsibilities on Notifications to Resid...

    Latest Blogs

    13 January 2020
    REAC Inspections
    Resident Involvement in REAC/NSPIRE Inspection Process​​As part of the NSPIRE pilot process, HUD has announced that additional processes will be added to engage the residents in the REAC/NSPIRE process. You can read the press release on HUD's website...
    24 August 2019
    REAC Inspections
    On August 21, 2019, HUD published a set of proposed rules in the Federal Register "Notice of Demonstration To Assess the National Standards for the Physical Inspection of Real Estate and Associated Protocols" 24 CFR Parts 5 and 200; [Docket No. FR–6...
    21 August 2019
    REAC Inspections
    On August 20, 2019, HUD released the first of the new NSPIRE protocols which will be expected to become active once the pilot/demonstration program has concluded. This is a first look at what deficiencies will look like under NSPIRE, the inspection ...
    16 July 2019
    REAC Inspections
    July 8, 2019 HUD's Office of Multifamily Housing Asset Management and Oversight released a memorandum reiterating the rules surrounding notice prior to entering resident's units, availability of documentation for residents to review, and clarificati...
    09 July 2019
    REAC Inspections
    The House Financial Services Committee passed a bill - the Safe Housing for Families Act of 2019 (H.R. 1690), and it will likely move forward to a full vote in the near future. The bill provides $300 million over three years to fund the installation...