REAC Provides Clarification on Non-Industry Standards Rules and Determinations

Enter your text here ...HUD REAC Released a PowerPoint document (Click here) in an email to REAC Inspectors. This presentation is intended to provide clarify to sometimes subjective interpretations of what is considered to be "Non-Industry Standard" repairs. This document includeds a series of photogaphs with "Final Decisions" about what is considered to be a deficiency and what is not; much of this is contrary to previous statements and perceptions of the Non-Industry Standard Requirement. 

The primary concept of the Non-Industry Standard rule is that "All Repairs must be done in a good and workmanlike manner with materials which are suitable for the purpose and free of defects," – good and workmanlike is then defined as "finished in a manner which is reasonably compatible with the design and quality of the original and adjoining decorative materials"

HUD REAC/NSPIRE Clarifications on Non-Industry Standards 

  1. Repairs to asphalt parking lots using concrete are now considered to be acceptable 
  2. Peeling paint on a porch which is suspected to be lead-based paint was stated to be not be a current deficiency but will be included in a future update (peeling paint on a porch is actually already a deficiency, it can be recorded as Patio/Porch/Balcony, Level 3, damaged railing
  3. Repair to any surface with tape of any kind is not an acceptable form of repair 
  4. Siding and roofing repairs should not be cited as a deficiency for the materials being different styles and colors, so long as "the color and style are as close as possible and it is consistent throughout
  5. Siding and roofing repairs should be cited as a deficiency for the materials being different styles and colors, so long as "the color and style are close as possible" and "it is consistent throughout"
  6. Wood, Metal, and plastic wall gaurds are not a deficiency if they are installed to prevent wall damage
  7. Incorrect usage of weather stripping should be recorded as a damaged door seal.

Many of the clarifications included in this document provide some useful clarifications for REAC inspectors to follow, but the repairs shown as being "industry standard" still appear to be less than optimal repairs that are not properly addressing the issues. Please review this document with an eye towards understanding the standards being applied by REAC but it is not advised to adopt many of these standards as acceptable.​

Carbon Monoxide Detectors to Become Required in As...
HUD REAC Announces Outline for Participation in NS...

Latest Blogs

16 July 2019
REAC Inspections
July 8, 2019 HUD's Office of Multifamily Housing Asset Management and Oversight released a memorandum reiterating the rules surrounding notice prior to entering resident's units, availability of documentation for residents to review, and clarificati...
09 July 2019
REAC Inspections
The House Financial Services Committee passed a bill - the Safe Housing for Families Act of 2019 (H.R. 1690), and it will likely move forward to a full vote in the near future. The bill provides $300 million over three years to fund the installation...
05 June 2019
REAC Inspections
Enter your text here ...HUD REAC Released a PowerPoint document (Click here) in an email to REAC Inspectors. This presentation is intended to provide clarify to sometimes subjective interpretations of what is considered to be "Non-Industry Standard"...
01 June 2019
REAC Inspections
HUD Published a notice in the Federal Register on May 23, 2019 entitled "Notice of Emergency Approval of Information Collection for Physical Inspection of Real Estate (NSPIRE).: This notice includes information about developing a new standardized ele...
17 May 2019
REAC Inspections
On May 1, 2019, HUD Released a memorandum entitled "What to do when a Project Receives a Zero as a Result of an Owner Refusing to Allow HUD to Inspect." The notice clarifies a few areas:If a property fails to complete an inspection after the initial...

Blog Archive